Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Appl Mater Interfaces ; 15(1): 220-235, 2023 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-36416784

RESUMO

The present study interrogates the interaction of highly efficient antibacterial surfaces containing sharp nanostructures with blood proteins and the subsequent immunological consequences, processes that are of key importance for the fate of every implantable biomaterial. Studies with human serum and plasma pointed to significant differences in the composition of the protein corona that formed on control and nanostructured surfaces. Quantitative analysis using liquid chromatography-mass spectrometry demonstrated that the nanostructured surface attracted more vitronectin and less complement proteins compared to the untreated control. In turn, the protein corona composition modulated the adhesion and cytokine expression by immune cells. Monocytes produced lower amounts of pro-inflammatory cytokines and expressed more anti-inflammatory factors on the nanostructured surface. Studies using an in vivo subcutaneous mouse model showed reduced fibrous capsule thickness which could be a consequence of the attenuated inflammatory response. The results from this work suggest that antibacterial surface modification with sharp spike-like nanostructures may not only lead to the reduction of inflammation but also more favorable foreign body response and enhanced healing, processes that are beneficial for most medical devices implanted in patients.


Assuntos
Nanoestruturas , Coroa de Proteína , Humanos , Camundongos , Animais , Adsorção , Nanoestruturas/química , Proteínas Sanguíneas , Citocinas/metabolismo , Antibacterianos/farmacologia , Antibacterianos/química , Propriedades de Superfície , Adesão Celular/fisiologia
2.
Clin Orthop Relat Res ; 480(11): 2232-2250, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36001022

RESUMO

BACKGROUND: A nanostructured titanium surface that promotes antimicrobial activity and osseointegration would provide the opportunity to create medical implants that can prevent orthopaedic infection and improve bone integration. Although nanostructured surfaces can exhibit antimicrobial activity, it is not known whether these surfaces are safe and conducive to osseointegration. QUESTIONS/PURPOSES: Using a sheep animal model, we sought to determine whether the bony integration of medical-grade, titanium, porous-coated implants with a unique nanostructured surface modification (alkaline heat treatment [AHT]) previously shown to kill bacteria was better than that for a clinically accepted control surface of porous-coated titanium covered with hydroxyapatite (PCHA) after 12 weeks in vivo. The null hypothesis was that there would be no difference between implants with respect to the primary outcomes: interfacial shear strength and percent intersection surface (the percentage of implant surface with bone contact, as defined by a micro-CT protocol), and the secondary outcomes: stiffness, peak load, energy to failure, and micro-CT (bone volume/total volume [BV/TV], trabecular thickness [Tb.Th], and trabecular number [Tb.N]) and histomorphometric (bone-implant contact [BIC]) parameters. METHODS: Implants of each material (alkaline heat-treated and hydroxyapatite-coated titanium) were surgically inserted into femoral and tibial metaphyseal cancellous bone (16 per implant type; interference fit) and in tibial cortices at three diaphyseal locations (24 per implant type; line-to-line fit) in eight skeletally mature sheep. At 12 weeks postoperatively, bones were excised to assess osseointegration of AHT and PCHA implants via biomechanical push-through tests, micro-CT, and histomorphometry. Bone composition and remodeling patterns in adult sheep are similar to that of humans, and this model enables comparison of implants with ex vivo outcomes that are not permissible with humans. Comparisons of primary and secondary outcomes were undertaken with linear mixed-effects models that were developed for the cortical and cancellous groups separately and that included a random effect of animals, covariates to adjust for preoperative bodyweight, and implant location (left/right limb, femoral/tibial cancellous, cortical diaphyseal region, and medial/lateral cortex) as appropriate. Significance was set at an alpha of 0.05. RESULTS: The estimated marginal mean interfacial shear strength for cancellous bone, adjusted for covariates, was 1.6 MPa greater for AHT implants (9.3 MPa) than for PCHA implants (7.7 MPa) (95% CI 0.5 to 2.8; p = 0.006). Similarly, the estimated marginal mean interfacial shear strength for cortical bone, adjusted for covariates, was 6.6 MPa greater for AHT implants (25.5 MPa) than for PCHA implants (18.9 MPa) (95% CI 5.0 to 8.1; p < 0.001). No difference in the implant-bone percent intersection surface was detected for cancellous sites (cancellous AHT 55.1% and PCHA 58.7%; adjusted difference of estimated marginal mean -3.6% [95% CI -8.1% to 0.9%]; p = 0.11). In cortical bone, the estimated marginal mean percent intersection surface at the medial site, adjusted for covariates, was 11.8% higher for AHT implants (58.1%) than for PCHA (46.2% [95% CI 7.1% to 16.6%]; p < 0.001) and was not different at the lateral site (AHT 75.8% and PCHA 74.9%; adjusted difference of estimated marginal mean 0.9% [95% CI -3.8% to 5.7%]; p = 0.70). CONCLUSION: These data suggest there is stronger integration of bone on the AHT surface than on the PCHA surface at 12 weeks postimplantation in this sheep model. CLINICAL RELEVANCE: Given that the AHT implants formed a more robust interface with cortical and cancellous bone than the PCHA implants, a clinical noninferiority study using hip stems with identical geometries can now be performed to compare the same surfaces used in this study. The results of this preclinical study provide an ethical baseline to proceed with such a clinical study given the potential of the alkaline heat-treated surface to reduce periprosthetic joint infection and enhance implant osseointegration.


Assuntos
Anti-Infecciosos , Osseointegração , Animais , Anti-Infecciosos/farmacologia , Durapatita/farmacologia , Humanos , Próteses e Implantes , Ovinos , Propriedades de Superfície , Titânio/farmacologia
3.
Biointerphases ; 17(3): 031003, 2022 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-35589426

RESUMO

Cardiovascular disease is a leading cause of death worldwide; however, despite substantial advances in medical device surface modifications, no synthetic coatings have so far matched the native endothelium as the optimal hemocompatible surface for blood-contacting implants. A promising strategy for rapid restoration of the endothelium on blood-contacting biomedical devices entails attracting circulating endothelial cells or their progenitors, via immobilized cell-capture molecules; for example, anti-CD34 antibody to attract CD34+ endothelial colony-forming cells (ECFCs). Inherent is the assumption that the cells attracted to the biomaterial surface are bound exclusively via a specific CD34 binding. However, serum proteins might adsorb in-between or on the top of antibody molecules and attract ECFCs via other binding mechanisms. Here, we studied whether a surface with immobilized anti-CD34 antibodies attracts ECFCs via a specific CD34 binding or a nonspecific (non-CD34) binding. To minimize serum protein adsorption, a fouling-resistant layer of hyperbranched polyglycerol (HPG) was used as a "blank slate," onto which anti-CD34 antibodies were immobilized via aldehyde-amine coupling reaction after oxidation of terminal diols to aldehydes. An isotype antibody, mIgG1, was surface-immobilized analogously and was used as the control for antigen-binding specificity. Cell binding was also measured on the HPG hydrogel layer before and after oxidation. The surface analysis methods, x-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry, were used to verify the intended surface chemistries and revealed that the surface coverage of antibodies was sparse, yet the anti-CD34 antibody grafted surface-bound ECFCs very effectively. Moreover, it still captured the ECFCs after BSA passivation. However, cells also attached to oxidized HPG and immobilized mIgG1, though in much lower amounts. While our results confirm the effectiveness of attracting ECFCs via surface-bound anti-CD34 antibodies, our observation of a nonspecific binding component highlights the importance of considering its consequences in future studies.


Assuntos
Anticorpos , Células Endoteliais , Anticorpos/metabolismo , Antígenos CD34/metabolismo , Contagem de Células
4.
ACS Appl Bio Mater ; 3(6): 3718-3730, 2020 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35025243

RESUMO

Hyperbranched polyglycerol (HPG) was previously investigated as a nonfouling hydrophilic grafted layer on biomaterial surfaces, analogous to the well-known poly(ethylene oxide) (PEO), but the range of adsorbing cells and proteins tested was limited and at times the assays used were not the most sensitive. Thus, the questions arise whether HPG-grafted layers can indeed efficiently resist adsorption of a wider range of adsorbing biological entities, and how would different biological entities interact with such a coating. An HPG coating of 25 nm thickness was grafted onto a spin-coated and plasma-treated polystyrene (PS) layer on a silicon wafer substrate; this provided a well-suited system for surface analyses by X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (ToF-SIMS), and atomic force microscopy (AFM), which verified the presence of a uniform, smooth grafted HPG layer. Adsorption of bovine serum albumin, lysozyme, fibrinogen, and endothelial cell growth medium 2 (EGM2) was reduced by >90%, with the adsorbed amounts close to the detection limit of XPS but still detectable by ToF-SIMS using principal component analysis. With human serum, however, the reduction in adsorption was slightly less pronounced. Smooth muscle cells (SMCs) and fibroblasts were virtually unable to attach onto the grafted HPG layer, with >99% reductions at 6 h compared with plasma-treated PS; the few attached cells remaining rounded and unable to spread. Their attachment might have resulted from coating defects. Testing with full blood showed that unlike for the control surface (plasma-treated PS), platelets did not adhere to the HPG surface, but there was attachment of some cells that stained CD11b positive and likely are neutrophils. Cells of the fungal organism Candida albicans were also able to attach onto the HPG surface to a limited extent, but in contrast to the control surface, the attached cells on HPG did not form hyphal extensions and thus seem to be compromised in their ability to invade and to form biofilms. Our data suggest that "low-fouling" is a better term than nonfouling for a grafted HPG layer as the resistance to adsorption is not uniform across a range of proteins and cells. It is also important in future work to study whether the cells that do attach can still exert their normal functions; our observation of the absence of hyphal extensions for C. albicans suggests that this may not be so. Hence, the potential utility of a grafted HPG layer may be not just a function of adsorbed amounts but also of the functionality of adsorbed proteins and cells.

5.
Biointerphases ; 14(1): 011002, 2019 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-30700091

RESUMO

PolyJet three-dimensional (3D) printing allows for the rapid manufacturing of 3D moulds for the fabrication of cross-linked poly(dimethylsiloxane) microwell arrays (PMAs). As this 3D printing technique has a resolution on the micrometer scale, the moulds exhibit a distinct surface roughness. In this study, the authors demonstrate by optical profilometry that the topography of the 3D printed moulds can be transferred to the PMAs and that this roughness induced cell adhesive properties to the material. In particular, the topography facilitated immobilization of endothelial cells on the internal walls of the microwells. The authors also demonstrate that upon immobilization of endothelial cells to the microwells, a second population of cells, namely, pancreatic islets could be introduced, thus producing a 3D coculture platform.


Assuntos
Adesão Celular , Células Imobilizadas/fisiologia , Técnicas de Cocultura/métodos , Dimetilpolisiloxanos/metabolismo , Células Endoteliais/fisiologia , Células Secretoras de Glucagon/fisiologia , Células Secretoras de Insulina/fisiologia , Humanos , Ilhotas Pancreáticas , Impressão Tridimensional , Propriedades de Superfície
6.
Biomacromolecules ; 18(6): 1697-1704, 2017 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-28437084

RESUMO

The propensity of glycosaminoglycans to mediate cell-cell and cell-matrix interactions opens the door to capture cells, including circulating blood cells, onto biomaterial substrates. Chondroitin sulfate (CS)-B is of particular interest, since it interacts with the receptor (EGF)-like module-containing mucin-like hormone receptor-like 2 precursor (EMR2) displayed on the surface of leukocytes and endothelial progenitor cells. Herein, CS-B and its isomer CS-A were covalently immobilized onto heptylamine plasma polymer films via three different binding chemistries to develop platform technology for the capture of EMR2 expressing cells onto solid carriers. Surface characterization verified the successful immobilization of both glycosaminoglycans. The EMR2 expressing human myeloid cell line U937 preferentially bound onto CS-B-modified substrates, and U937 cells preincubated with CS-B in solution exhibited reduced affinity for the substrate. The direct capture of hematopoietic and blood-circulating endothelial cell types via a glycosaminoglycan-binding surface receptor opens an unexplored route for the development of biomaterials targeted at these cell types.


Assuntos
Separação Celular/métodos , Materiais Revestidos Biocompatíveis/química , Dermatan Sulfato/química , Receptores Acoplados a Proteínas G/metabolismo , Aminas/química , Adesão Celular , Sulfatos de Condroitina/química , Materiais Revestidos Biocompatíveis/metabolismo , Dermatan Sulfato/metabolismo , Expressão Gênica , Humanos , Gases em Plasma , Ligação Proteica , Receptores Acoplados a Proteínas G/genética , Propriedades de Superfície , Células U937
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...